€183.00
5 vorrätig
Engineered for reliable ignition and long-term cyclic performance, the Sinergy B575029SMF Sealed Maintenance Free (SMF) automotive battery delivers robust 540CCA cold starting power. Built in a standard D26 JIS casing with integrated B1 base hold-downs, it provides high vibration resistance and durable starting power for modern passenger vehicles and light utility trucks.
The Sinergy B575029SMF automotive battery is engineered to deliver high starting reliability and consistent electrical throughput across demanding automotive environments. Built around an advanced 6-cell lead-acid configuration operating at a nominal 12V, this battery combines high-density active material formulations with calcium-alloy stamped grids to reduce internal electrical resistance and mitigate grid growth. Rated at 75Ah capacity with 540 Cold Cranking Amps (CCA), it supplies sustained cranking current during low-temperature ignition cycles when engine oil viscosity peaks and starter motor draw is at its highest.
Vibration durability is central to the design of the B575029SMF. Automotive engine compartments subject electrical storage units to continuous harmonic oscillation, rough road impacts, and elevated thermal stress. Sinergy addresses active material shedding by incorporating reinforced plate envelopes and anchored cell assemblies within a rigid polypropylene case. This robust construction safeguards active paste adherence to positive and negative lead grids, mitigating internal short-circuits and extending battery operating life under severe driving conditions.
As a Sealed Maintenance Free (SMF) power unit, the battery integrates an internal labyrinth double-lid condensation system. Micro-porous flame arrestor discs allow controlled venting of pressure while capturing and condensing electrolyte vapors back into the cell reservoirs. This completely sealed architecture eliminates the need for demineralized water top-ups throughout the service life of the battery, offering a spill-resistant, clean, and worry-free solution for daily driving.
| Spezifikationsparameter | Technischer Wert |
|---|---|
| Marke | Sinergy |
| Part / SKU Number | B575029SMF |
| Nennspannung | 12V (2.0V x 6 cells) |
| Nennkapazität (C20) | 75 Ah |
| Cold Cranking Amps (CCA / SAE) | 540 CCA |
| Box Size / Group Standard | JIS D26 |
| Außenmaße (L x B x H) | 257 x 172 x 220 mm |
| Hold Down Configuration | B1 |
| Technology Type | Sealed Maintenance Free (SMF) Ca/Ca |
| Terminal-Typ | Standard Automotive Tapered Posts |
The D26 case profile (257mm x 172mm x 220mm) is one of the most widely deployed formats across Asian and European automotive platforms, fitting passenger sedans, crossover SUVs, and light utility vehicles. Equipped with a B1 hold-down notch along the base, the Sinergy B575029SMF locks securely into factory battery trays, maintaining stable physical retention without requiring customized bracket modifications.
For standard internal combustion engines equipped with modern auxiliary loads—such as infotainment touchscreens, seat heaters, GPS systems, and active safety sensors—the 75Ah reserve capacity supplies substantial buffer power to offset generator variations. However, it is important to note that standard flooded and SMF calcium batteries are engineered strictly for conventional starting, lighting, and ignition (SLI) duty cycles. They are not intended for micro-hybrid vehicles utilizing regenerative braking or aggressive automatic idle Start-Stop systems, which require specialized EFB (Enhanced Flooded Battery) or AGM (Absorbent Glass Mat) chemistries to withstand continuous micro-cycling at partial states of charge.
Installing an SMF battery into a vehicle requiring an AGM or EFB unit can lead to rapid premature plate sulfation and early system failure. Always verify whether your vehicle features an automatic Start-Stop engine shutoff before selecting an SMF replacement, ensuring the charging profile and current acceptance match factory manufacturer specifications.
Ensure vehicle ignition is completely off and keys removed prior to battery removal. Disconnect the negative (ground) terminal cable first to avoid accidental short-circuits with your hand tools, followed by the positive cable. Inspect the battery tray, clean away dirt and corrosive buildup, and verify that the B1 hold-down clamping bracket is intact. Carefully place the Sinergy B575029SMF into the tray, ensuring proper seating along the base retention rim.
Attach the positive cable clamp first, followed by the negative cable clamp. Tighten terminals securely to prevent high-resistance contact points, but do not overtighten, which can distort or fracture the soft lead posts. Applying a thin coat of dielectric grease or terminal protection spray over external surfaces helps prevent atmospheric oxidation and corrosion. For vehicles stored long-term or driven exclusively on short urban trips, periodically connect a smart multi-stage maintenance charger to maintain open-circuit voltage at or above 12.6V, mitigating parasitic discharge and plate sulfation.
No, this battery utilizes standard Sealed Maintenance Free (SMF) calcium lead-acid technology designed for conventional starting systems. Vehicles equipped with automatic Start-Stop systems require specialized EFB or AGM batteries designed to handle continuous high-rate cycling without degrading active plate material.
D26 is a standard Japanese Industrial Standard (JIS) casing dimension denoting a battery housing roughly 26cm in length. Specifically, the Sinergy B575029SMF measures 257mm long, 172mm wide, and 220mm high to terminal top, providing a drop-in fit for corresponding OEM trays.
No, the Sinergy B575029SMF is completely maintenance-free. It features an integrated double-lid recombination system that condenses outgassed water back into the electrolyte chambers, permanently sealing the battery against fluid loss during standard operation.
The B1 specification indicates specific molded retention ledges along the long sides of the bottom case perimeter. These ledges allow vehicle base clamp brackets to anchor the battery directly to the chassis floor tray.
Measure the resting open-circuit voltage using a digital multimeter across the terminals. A fully charged 12V 6-cell calcium battery will read between 12.6V and 12.8V at room temperature. If the reading is below 12.4V, top it off using an automotive smart charger prior to putting it into service.
| Gewicht | 6967131678 kg |
|---|
Geprüfte technische Daten, Informationen zur Fahrzeugkompatibilität und Antworten zu Wartungsfragen.
No, this battery is not suitable for vehicles equipped with micro-hybrid Start-Stop (ISS) technology. The Sinergy D26 SMF is built with standard Sealed Maintenance-Free (Calcium/Calcium) flooded battery architecture designed for conventional internal combustion engines with standard charging cycles. Start-Stop applications require batteries with rapid dynamic charge acceptance and ultra-high cyclic endurance, such as Enhanced Flooded Battery (EFB) or Absorbent Glass Mat (AGM) units. Fitting this standard SMF battery into a Start-Stop vehicle will cause severe plate stress, active material shedding, and premature failure within months.
To safely recharge and maintain the B575029SMF, utilize a smart, multi-stage microprocessor charger programmed for flooded/calcium lead-acid chemistry. The recommended bulk and absorption charging voltage is 14.4V to 14.8V at 25°C, with a temperature compensation coefficient of -3mV/°C per cell. Once 100% state-of-charge is reached, the float charge must step down to 13.5V–13.8V to prevent thermal runaway and electrolyte loss. The maximum recommended initial charge current should not exceed 10% to 15% of the nominal capacity (approximately 7.5A to 11.2A). Never use unregulated continuous-voltage chargers above 15.0V on this sealed unit.
Under normal operating conditions in non-commercial passenger applications, the Sinergy D26 75Ah has an expected operating lifespan of 3 to 5 years. Standard commercial manufacturer warranty coverage typically spans 24 to 36 months, depending on retailer agreements and application classification (private vs. commercial/taxi use). Operating life is governed by alternator health, ambient engine bay temperatures, and driving profiles; chronic short trips that leave the battery in a partial state of charge (below 12.4V) or continuous exposure to engine bay heat exceeding 50°C will accelerate grid corrosion and shorten functional life.
The 540 Cold Cranking Amperes (CCA) rating indicates that the battery can discharge 540 amperes at -18°C (0°F) for 30 seconds while maintaining a terminal voltage above 7.2 volts under standard SAE J537 testing. In freezing winter conditions, internal electrolyte resistance rises and engine oil viscosity increases significantly; 540CCA delivers ample instantaneous breakaway torque to reliably crank 4-cylinder and standard 6-cylinder naturally aspirated petrol engines, as well as moderate 2.0L–2.5L diesel engines. In sub-zero climates, maintaining a full resting open-circuit voltage of 12.6V+ is critical to ensure peak cranking current delivery.
The B575029SMF is completely maintenance-free; its sealed calcium grid design and internal labyrinth cover condense and recombine vented gases, meaning distilled water never needs to be replenished. For installation, always verify the JIS D26 terminal layout (terminal polarity orientation must match your vehicle's harness reach without stretching cables). When replacing: disconnect the negative (black/-) earth terminal first, then the positive (red/+). During installation, connect the positive terminal first and torque terminals to standard specifications (4–6 Nm) to avoid cracking the lead bushings. Ensure the vehicle hold-down clamp is firm without warping the casing, and ensure the integrated side flame-arrestor vent ports remain completely unobstructed.

Autobatterien, Leichtfahrzeuge, WET-Technologie

Autobatterien, japanischer Typ, Leichtfahrzeuge, Nasszellen-Technologie

Autobatterien, EFB, japanischer Typ, Leichtfahrzeuge

Car Batteries, Auxiliary Battery