


€408.41
5 σε απόθεμα
The Sinergy SINERGY 12V Battery (SKU: B680022100) delivers dependable starting power, high cyclic endurance, and reliable electrical output under heavy vehicle loads. Manufactured with heavy-duty calcium-alloy grids and leak-proof internal construction, this unit provides long-term reliability in extreme hot and cold weather environments.
The Sinergy SINERGY 12V Lead-Acid Starting Battery (SKU: B680022100) is built to meet the rigorous demands of contemporary passenger vehicles, commercial light fleets, and utility equipment. Designed by automotive power storage engineers, this unit incorporates high-density expanded lead-calcium-tin grids that dramatically reduce self-discharge, prevent internal plate growth, and resist electrolyte gassing. The continuous alloy structure delivers low internal resistance, enabling rapid current discharge under heavy load.
Cold cranking performance is a primary benchmark for modern starting systems, and the Sinergy 12V architecture provides sustained amperage delivery even when ambient temperatures fall to sub-zero levels. Advanced active mass paste formulation coats the internal grid plates, maximizing contact surface area with the liquid electrolyte. This optimized electrochemical interface allows the battery to reliably deliver high surge currents to overcome engine oil viscosity during freezing winter morning starts.
Mechanical integrity is reinforced via reinforced polypropylene casing featuring built-in anchor ribs and shock-dampening plate bridges. Automotive and light commercial platforms expose power units to continuous high-frequency vibration and lateral chassis movement; the B680022100 isolates the internal cell stacks against mechanical stress, effectively preventing active material shedding and internal short circuits. The sealed labyrinth lid system continuously condenses outgassed water vapors, recycling moisture back into the reservoir cells for a 100% maintenance-free operating lifecycle.
| Παράμετροι προδιαγραφών | Engineering Value |
|---|---|
| Ονομαστική τάση | 12 βολτ |
| Nominal Capacity (C20 Rate) | 180 Ah |
| Cold Cranking Amperage (CCA EN -18°C) | 1000 A |
| DIN Box / Case Code | L2 (DIN 027) |
| Εξωτερικές διαστάσεις (Μ x Π x Υ) | 513 mm × 223 mm × 223 mm |
| Τύπος ακροδέκτη | Standard Conical A-Pole (EN / SAE) |
| Διάταξη πολικότητας ακροδεκτών | Θετικό δεξί χέρι (Διάταξη 0) |
| Τύπος φλάντζας συγκράτησης | B13 (Base mounting ledges on all sides) |
| Electrochemical Technology | Sealed Maintenance-Free (SMF) Pb-Ca/Ca |
| Ventilation & Safety | Integrated Dual Flame Arrestor Ports |
The Sinergy B680022100 is engineered primarily for vehicles requiring robust standard starting, lighting, and ignition (SLI) capabilities. Its dimensional footprint conforms to standard DIN L2 sizing, making it a direct-fit replacement for dozens of European, Asian, and domestic automotive platforms requiring clean DC power supply to support anti-lock braking systems (ABS), transmission control units, onboard navigation, and modern infotainment systems.
For vehicles equipped with high-frequency micro-hybrid regenerative braking and intensive Start-Stop cycling, proper battery chemistry matching is critical. While the Sinergy SMF platform supports rapid micro-recharging and standard alternators, vehicles factory-configured with deep cyclic Start-Stop systems demand EFB (Enhanced Flooded Battery) or AGM (Absorbent Glass Mat) standards. Operating this SLI battery in standard non-start-stop vehicles or moderate accessory setups guarantees peak lifecycle performance and stable voltage regulation across high alternator charge outputs.
Proper mechanical and electrical installation ensures maximum operational lifespan for the Sinergy 12V battery. Prior to mounting, inspect the vehicle battery tray for debris, rust, or distortion. Always disconnect the negative (black/ground) terminal first during removal of the depleted battery, and reconnect the positive (red) lead first when seating the new Sinergy unit. Secure the base hold-down clamp to the B13 flange with factory-specified torque to eliminate excessive vibration without warping the outer battery container.
Terminals must remain clean, free of oxidation, and lightly treated with non-conductive dielectric grease or terminal protector spray after securing terminal lugs. If the vehicle is parked for extended winter storage or undergoes infrequent short journeys, maintain open-circuit terminal voltage above 12.4V using a microprocessor-controlled smart multi-stage maintenance charger to avoid irreversible lead-sulfate crystallization on the negative plates.
No. The Sinergy B680022100 is a premium Sealed Maintenance-Free (SMF) SLI battery engineered for conventional internal combustion vehicles. Vehicles featuring automated Start-Stop systems with kinetic regenerative charging require heavy-duty EFB or AGM chemistries to survive accelerated micro-cycling.
No. This battery features a sealed Calcium/Calcium formulation that minimizes water electrolysis and fluid evaporation. The sealed labyrinth cover recovers and recirculates internal vapor, delivering maintenance-free performance without liquid replenishment ports.
This unit provides 620 Cold Cranking Amps measured at -18°C according to standard EN testing protocol, ensuring reliable cranking torque for medium-displacement petrol and turbo-diesel passenger engines.
The Sinergy B680022100 features a Layout 0 configuration, meaning the positive terminal is situated on the right-hand side when viewing the battery from the front edge with the terminals closest to you.
A healthy, fully charged 12V calcium battery at room temperature should read between 12.65V and 12.80V open-circuit voltage across the terminals when tested with an accurate digital voltmeter after resting for at least four hours off the charger.
| Βάρος | 6967131678 κ. |
|---|---|
| Διαστάσεις | 51.3 × 22.3 × 22.3 cm |
Επαληθευμένες τεχνικές προδιαγραφές, πληροφορίες σχετικά με τη συμβατότητα των οχημάτων και απαντήσεις σε ερωτήσεις σχετικά με τη συντήρηση.
No. The Sinergy B680022100 is a premium Sealed Maintenance-Free (SMF) SLI battery engineered for conventional internal combustion vehicles. Vehicles featuring automated Start-Stop systems with kinetic regenerative charging require heavy-duty EFB or AGM chemistries to survive accelerated micro-cycling.
No. This battery features a sealed Calcium/Calcium formulation that minimizes water electrolysis and fluid evaporation. The sealed labyrinth cover recovers and recirculates internal vapor, delivering maintenance-free performance without liquid replenishment ports.
This unit provides 620 Cold Cranking Amps measured at -18u00b0C according to standard EN testing protocol, ensuring reliable cranking torque for medium-displacement petrol and turbo-diesel passenger engines.
The Sinergy B680022100 features a Layout 0 configuration, meaning the positive terminal is situated on the right-hand side when viewing the battery from the front edge with the terminals closest to you.
A healthy, fully charged 12V calcium battery at room temperature should read between 12.65V and 12.80V open-circuit voltage across the terminals when tested with an accurate digital voltmeter after resting for at least four hours off the charger.

Ιαπωνικού τύπου, μπαταρίες εκκίνησης, τεχνολογία WET

Ιαπωνικού τύπου, μπαταρίες εκκίνησης, τεχνολογία WET

Μπαταρίες εκκίνησης, τεχνολογία WET

Μπαταρίες εκκίνησης, τεχνολογία WET


Made with ♥ by eMarketing Cyprus
