€27.10
The Sinergy SIN6-3.2A is a high-performance 6V 3.2Ah sealed lead-acid (VRLA) battery engineered for reliable cyclic and standby power delivery. Featuring an ultra-slim 134x24x60 mm footprint and premium micro-porous AGM separators, it delivers maintenance-free, fully sealed operation across specialized low-voltage, security, and powersports backup equipment.
The Sinergy SIN6-3.2A (SKU: 434571) is a specialized 6-Volt valve-regulated lead-acid (VRLA) battery meticulously engineered for mission-critical reliability, cyclic stamina, and float performance. Constructed using a true 3-cell internal configuration delivering 2.0V nominal potential per cell, this compact powerhouse provides an exact 6.0V nominal output calibrated to eliminate parasitic voltage drop in sensitive electronic and electromechanical applications. Its refined lead-calcium-tin alloy plate grids drastically suppress internal gassing and water loss, ensuring that internal active material remains chemically intact over years of continuous service.
Internally, the Sinergy SIN6-3.2A utilizes advanced Absorbent Glass Mat (AGM) technology. High-purity borosilicate glass fiber separators absorb and immobilize 100% of the liquid sulfuric acid electrolyte. This dry-fit configuration not only provides superior shock and vibration resistance against mechanical impacts but also guarantees an oxygen recombination efficiency exceeding 99%. Because the recombination reaction neutralizes internal pressure through an integrated self-resealing rubber safety relief valve, the battery operates safely in any orientation without the risk of acid leakage, terminal corrosion, or caustic environmental venting.
The electrochemistry of the SIN6-3.2A produces remarkably low internal resistance, enabling rapid discharge rates when instantaneous peak current is demanded. Whether supporting intermittent high-drain bursts in emergency lighting arrays or providing stable, ripple-free current to precision sensors, telemetry units, and medical monitors, this 3.2Ah battery maintains high terminal voltage throughout its full discharge cycle. Its self-discharge rate is exceptionally low, retaining peak state-of-charge for months of inactive shelf storage under controlled conditions.
| Параметр | Engineering Specification |
|---|---|
| Manufacturer / Line | Sinergy Industrial & Powersports |
| Model / Part Number | SIN6-3.2A (SKU: 434571) |
| Номинальное напряжение | 6V (3 Cells @ 2.0V/Cell) |
| Номинальная мощность (C20) | 3.2 Ah (20-Hour Rate to 1.75V/Cell) |
| Внутренние технологии | Valve Regulated Lead-Acid (VRLA / AGM Recombinant) |
| Тип терминала | F1 Faston Tab (4.75 mm / 0.187 inch) |
| Размеры (Д × Ш × В) | 134 mm x 24 mm x 60 mm (5.28 x 0.94 x 2.36 inches) |
| Total Weight | 0.65 kg (1.43 lbs) |
| Container Material | Heavy-Duty Flame-Retardant ABS (UL94-HB Standard) |
| Float Charging Voltage | 6.75V to 6.90V at 25°C (77°F) |
| Cyclic Charging Voltage | 7.20V to 7.50V at 25°C (77°F) |
| Maximum Recommended Charging Current | 0.96 Amps (0.3C limit) |
| Диапазон рабочих температур | Discharge: -15°C to 50°C | Charge: -10°C to 40°C |
Due to its 6V nominal voltage and 3.2Ah capacity, the Sinergy SIN6-3.2A is engineered specifically for sub-12V electrical systems and secondary auxiliary networks. It is NOT compatible with modern 12V automotive starter systems or high-rate micro-hybrid Start-Stop automotive engines, which require heavy automotive 12V SLI (Starting, Lighting, Ignition) batteries rated upwards of 400 to 900 Cold Cranking Amps. Installing a 6V battery in a 12V automotive circuit will result in electrical mismatch and immediate equipment failure.
However, within the powersports, vintage, and mobility sectors, the SIN6-3.2A serves as an essential power source. It seamlessly powers classic 6-volt mopeds, vintage motorcycles, small scooters, motorized ride-on children vehicles, golf accessory electronics, and specialty electric equipment. Its slim 24 mm width allows it to slide cleanly into ultra-confined chassis bays where traditional box batteries cannot fit. Furthermore, it operates reliably as an uninterruptible power supply (UPS) backup battery, energizing automated access gates, commercial fire and intruder alarm systems, exit illumination, and portable lab instruments.
Proper installation ensures maximum cyclic longevity and safety. Prior to installation, inspect the terminal blades and housing for any shipping damage. Because this model is equipped with standard F1 Faston (4.75 mm) push-on quick-disconnect terminals, use matching female spade connectors crimped tightly with automotive-grade ratcheting crimpers. Avoid soldering directly to the terminal blades, as excess heat conducted through the terminal lead posts can melt the internal ABS seals and compromise the sealed VRLA barrier.
When securing the battery into your enclosure or vehicle cradle, ensure the unit is firmly clamped to prevent excessive mechanical movement. Thanks to its sealed AGM construction, the SIN6-3.2A can be mounted upright or horizontally on its sides; inverted mounting (terminals facing straight down) is not recommended. Always charge the battery with an intelligent multi-stage VRLA-compatible 6V smart charger. Avoid deep discharging past 5.25V (1.75V per cell), and apply a float charge of 6.75V to 6.90V during long periods of seasonal storage to prevent irreversible lead sulfation.
No. Modern Start-Stop vehicles operate on 12-volt electrical architectures requiring 12V AGM or EFB starting batteries with high Cold Cranking Amps (CCA). The Sinergy SIN6-3.2A is a 6-volt, 3.2Ah auxiliary and specialty battery designed for 6V devices, vintage light powersports, and backup systems.
VRLA stands for Valve Regulated Lead-Acid. This design features fully sealed casing, oxygen-recombining AGM separators, and one-way pressure-relief valves. It prevents electrolyte spillage, eliminates the need to add distilled water, and ensures complete maintenance-free operation.
The battery measures precisely 134 mm in length, 24 mm in width, and 60 mm in height, with a lightweight net mass of 0.65 kg (1.43 lbs). It is equipped with standard F1 (4.75 mm / 0.187 inch) Faston terminals.
Yes. Connecting two 6V 3.2Ah batteries in series (negative terminal of the first battery connected to the positive terminal of the second) creates a 12V 3.2Ah battery bank. Ensure both batteries are of the same age, brand, state of charge, and manufacturing batch before linking them.
For standby/float service, use a regulated charging voltage between 6.75V and 6.90V at 25°C. For cyclic discharge applications, use a charge voltage between 7.20V and 7.50V at 25°C, ensuring the maximum charging current does not exceed 0.96 Amps.
| Вес | 6967131678 кг |
|---|---|
| Габариты | 13.4 × 3.4 × 6 см |
Подтвержденные технические характеристики, информация о совместимости автомобилей и ответы на вопросы по техническому обслуживанию.
No, this battery is not compatible with modern Start-Stop systems. Automotive Start-Stop technology operates on a 12-volt electrical architecture requiring dedicated 12V AGM (Absorbent Glass Mat) or EFB (Enhanced Flooded Battery) platforms engineered for high-frequency micro-cycling. This 6-volt VRLA unit is designed for vintage/classic vehicles, specialty equipment, or multi-battery series configurations, and cannot fulfill the voltage or cyclic energy demands of modern Start-Stop vehicles.
You must use an intelligent, multi-stage microprocessor-controlled charger with a dedicated 6V VRLA/AGM profile. For cyclic/absorption charging, the voltage must be regulated between 7.20V and 7.40V at 25°C (2.40V–2.47V per cell). For standby/float charging, maintain between 6.75V and 6.90V (2.25V–2.30V per cell). Never use unregulated conventional chargers or 12V chargers, as exceeding these thresholds causes thermal runaway and forces the internal safety valves to vent, causing irreversible electrolyte loss and premature capacity failure.
Under standard operating conditions and proper charging maintenance, this 6V VRLA battery features an expected service life of 3 to 5 years. Typical commercial and automotive warranty coverage ranges from 12 to 24 months, subject to operational conditions. Longevity is strictly dependent on operating temperature and depth of discharge (DoD); continuous exposure to temperatures above 25°C (77°F) accelerates positive grid corrosion and plate degradation, halving the expected battery life for every 10°C increase.
Thanks to its VRLA construction—which tightly compresses the active material and reduces internal resistance compared to traditional flooded designs—this battery provides solid high-rate discharge and Cold Cranking Amps (CCA) in cold weather down to -18°C (0°F). However, chemical kinetics naturally decrease in sub-zero temperatures, temporarily diminishing effective cranking capacity by roughly 30% to 40%. To ensure reliable starting in extreme cold, the battery must be kept at a 100% State of Charge (SOC), which also lowers the freezing point of the electrolyte to below -50°C.
Yes, this VRLA battery is completely maintenance-free; internal oxygen recombination eliminates the need to add distilled water, and the sealed casing should never be punctured or opened. During installation, always verify vehicle polarity with a digital multimeter before connecting leads. Many classic 6-volt applications utilize a 'positive-ground' (positive earth) chassis system, contrasting with modern negative-ground configurations. Reversing terminal connections will cause immediate electrical burnouts, diode bridge destruction, and terminal melting.

UPS & Alarm Backup Batteries

UPS & Alarm Backup Batteries

Batteries, UPS & Alarm Backup Batteries

Batteries, UPS & Alarm Backup Batteries


Made with ♥ by eMarketing Cyprus