€263.11
5 σε απόθεμα
The Sinergy BSSD26EFB 12V Enhanced Flooded Battery (EFB) is engineered to deliver reliable cyclic endurance and high-amperage starting output for modern micro-hybrid and standard passenger vehicles. Designed with advanced carbon-infused active material and reinforced plate architecture, it handles heavy auxiliary loads and constant engine restart cycles effortlessly.
The Sinergy BSSD26EFB 12V battery stands at the forefront of electrochemical engineering, designed specifically to meet the high-demand cycling requirements of modern vehicles equipped with standard Start-Stop systems. Built utilizing high-density active material and advanced lead-calcium-tin alloy grids, this EFB unit drastically minimizes internal resistance while optimizing electron transfer. The structural integrity of the internal plates ensures steady high-rate discharge under sub-zero ambient conditions, providing dependable cold cranking amps when your engine needs it most.
A critical challenge for modern automotive power systems is dynamic charge acceptance (DCA). The BSSD26EFB addresses this through specially formulated negative plate carbon additives that prevent plate sulfation during frequent, shallow partial state-of-charge (PSoC) cycles. This chemistry significantly accelerates recharge efficiency from the alternator during braking and decelerating phases, keeping the battery primed and fully operational across continuous start-stop traffic patterns.
Durability under extreme road vibration is achieved through a robust polyester scrim bonded directly to the positive active mass. This retaining scrim secures the lead paste tightly against the grid frame, preventing shedding and grid degradation even when traversing harsh road surfaces or coping with high-heat engine bay conditions. The reinforced polypropylene outer casing provides structural rigidity, mitigating mechanical impact stresses and prolonging the overall operational lifespan of the power pack.
With up to twice the cyclic endurance of conventional flooded calcium batteries, the Sinergy BSSD26EFB serves as a robust powerhouse. Whether facing blistering summer heat or freezing winter mornings, its engineered balance of paste formulation, electrolyte distribution, and reinforced internal assembly guarantees sustained starting reliability and continuous auxiliary system operation without voltage sag.
| Προδιαγραφές | Λεπτομέρεια |
|---|---|
| Τάση | 12V |
| Nominal Capacity (20Hr Rate) | 70 Ah |
| Ρεύμα εκκίνησης σε κρύο (CCA EN) | 700 A |
| Case Standard / Box Code | JIS D26 (26R / 26L Platform) |
| Dimensions (L x W x H mm) | 260 mm x 173 mm x 225 mm |
| Τύπος ακροδέκτη | Standard Conical Post (SAE/DIN) |
| Φλάντζα συγκράτησης | B1 / Flat Base with Adaptable Lip |
| Χημεία μπαταριών | Enhanced Flooded Battery (EFB) |
| Maintenance Level | Maintenance-Free (Sealed Labyrinth Lid) |
Modern micro-hybrid and entry-level Start-Stop combustion platforms impose tremendous mechanical and electrical burdens on energy storage systems. Vehicles fitted with intelligent battery sensors (IBS), regenerative braking systems, and comprehensive infotainment arrays demand a battery capable of rapid energy turnover. The Sinergy BSSD26EFB fulfills these exact parameters, providing steady voltage stabilization for sensitive onboard components such as collision-avoidance radar, electronic power steering, and multi-zone climate controls while the internal combustion engine is briefly deactivated at traffic stops.
Beyond automotive start-stop duty, the BSSD26EFB is an exceptional power source for standard non-start-stop vehicles operating in high-demand environments. Delivery fleets, municipal service vehicles, commercial utility vans, and powersports chase vehicles with auxiliary winches, dual-battery relays, and high-wattage lighting rigs heavily benefit from the reinforced plate density and cycling reserves of this battery. Its standard JIS D26 footprint allows straightforward drop-in installation across a wide range of Japanese, Korean, and domestic vehicle chassis requiring reliable 12-volt delivery.
Safe and correct installation is vital to maximizing battery lifespan. Prior to replacing your existing unit, ensure the vehicle ignition and all electrical peripherals are entirely switched off to prevent transient voltage spikes. Remove the negative ground cable first, followed by the positive cable. Inspect the battery tray for debris or corrosion; clean thoroughly with a neutral baking soda solution if necessary. Position the Sinergy BSSD26EFB firmly into the tray and secure the hold-down bracket to prevent longitudinal and lateral vibration.
Prepare the battery terminals by clearing any microscopic oxidation with a wire brush. Reconnect the positive cable first, torque the clamp to manufacturer specification (typically between 5 and 7 Nm), and follow with the negative ground clamp. Coat the connection points with a thin layer of dielectric grease or acid-resistant terminal protector to prevent environmental oxidation. For vehicles equipped with an Intelligent Battery Sensor (IBS), ensure the battery management system (BMS) is reset via an OBD-II diagnostic tool to register the new battery capacity and calibrate optimal alternator charging parameters.
Yes. The Sinergy BSSD26EFB is an excellent upgrade for vehicles that originally came fitted with standard flooded lead-acid batteries. Its Enhanced Flooded Battery technology provides double the cyclic endurance, superior resistance to deep discharge, and faster dynamic recharging without requiring alterations to your standard charging system.
The BSSD26EFB is tailored for entry-level and standard Start-Stop vehicles that utilize an EFB power system from the factory. However, if your vehicle was originally fitted with an Absorbed Glass Mat (AGM) battery by the manufacturer, you should replace it with an AGM unit rather than an EFB, as AGM-equipped charging algorithms run at higher cyclic demands.
No. The Sinergy BSSD26EFB features an advanced sealed labyrinth dual-lid design that condenses electrolyte vapor and returns it directly to the internal cells. It is completely maintenance-free under standard regulated charging conditions, eliminating the need for periodic water additions.
Premature failure is typically caused by chronic undercharging from faulty alternators, prolonged partial state of charge without complete replenishment, severe parasitic drain from aftermarket accessories, or failing to register the new battery profile with the vehicle BMS on sensor-equipped modern cars.
If the vehicle is parked for more than a month, parasitic drains from modern alarm systems and computers can draw the battery down. We recommend connecting an intelligent multi-stage maintenance charger designed for EFB chemistry to maintain open-circuit voltage above 12.6V, avoiding destructive acid stratification and plate sulfation.
| Βάρος | 6967131678 κ. |
|---|---|
| Διαστάσεις | 26 × 17.3 × 22.5 cm |
Επαληθευμένες τεχνικές προδιαγραφές, πληροφορίες σχετικά με τη συμβατότητα των οχημάτων και απαντήσεις σε ερωτήσεις σχετικά με τη συντήρηση.
Yes. The Sinergy BSSD26EFB is an excellent upgrade for vehicles that originally came fitted with standard flooded lead-acid batteries. Its Enhanced Flooded Battery technology provides double the cyclic endurance, superior resistance to deep discharge, and faster dynamic recharging without requiring alterations to your standard charging system.
The BSSD26EFB is tailored for entry-level and standard Start-Stop vehicles that utilize an EFB power system from the factory. However, if your vehicle was originally fitted with an Absorbed Glass Mat (AGM) battery by the manufacturer, you should replace it with an AGM unit rather than an EFB, as AGM-equipped charging algorithms run at higher cyclic demands.
No. The Sinergy BSSD26EFB features an advanced sealed labyrinth dual-lid design that condenses electrolyte vapor and returns it directly to the internal cells. It is completely maintenance-free under standard regulated charging conditions, eliminating the need for periodic water additions.
Premature failure is typically caused by chronic undercharging from faulty alternators, prolonged partial state of charge without complete replenishment, severe parasitic drain from aftermarket accessories, or failing to register the new battery profile with the vehicle BMS on sensor-equipped modern cars.
If the vehicle is parked for more than a month, parasitic drains from modern alarm systems and computers can draw the battery down. We recommend connecting an intelligent multi-stage maintenance charger designed for EFB chemistry to maintain open-circuit voltage above 12.6V, avoiding destructive acid stratification and plate sulfation.

Ελαφρά οχήματα, Μπαταρίες εκκίνησης

Ελαφρά οχήματα, Μπαταρίες εκκίνησης

EFB, ιαπωνικού τύπου, ελαφρά οχήματα, μπαταρίες μίζας

Ελαφρά οχήματα, Μπαταρίες εκκίνησης


Made with ♥ by eMarketing Cyprus