€18.15
The Sinergy SIN6-4.5 (SIN6-45) is a high-performance, rechargeable 6V Valve Regulated Lead-Acid (VRLA) battery engineered for maximum dependability in cyclic and float standby applications. Designed with an advanced 3-cell architecture, high-efficiency Absorbent Glass Mat (AGM) separators, and standard F1 quick-disconnect terminals, this compact 0.72kg unit delivers steady, spill-proof DC power.
The Sinergy SIN6-4.5 (SKU: SIN6-45) represents robust engineering in compact energy storage, delivering dependable 6-volt direct current power across an extensive spectrum of industrial, standby, and light mobility systems. Engineered strictly in accordance with modern Valve Regulated Lead-Acid (VRLA) standards, this battery utilizes an optimized 3-cell configuration operating at 2.0V per cell to achieve an exact 6.0V nominal potential. Inside, high-purity lead-calcium-tin alloy grids reduce internal gassing and limit self-discharge to less than 3% per month at ambient temperatures, making it exceptionally reliable for long-term float service and seasonal operations.
Equipped with micro-porous glass fiber separators (AGM technology), the sulfuric acid electrolyte is fully absorbed and immobilized within the cell plates. This design guarantees leak-proof and spill-proof operation in virtually any orientation, while simultaneously offering resistance to severe shock and operational vibration. An integrated one-way self-resealing rubber pressure valve regulates internal atmospheric pressure, venting excess gas only under abnormal overcharge conditions before automatically re-sealing to prevent dry-out and air ingress.
With a rated capacity of 4.5Ah, the Sinergy SIN6-4.5 provides consistent discharge performance under both low-current steady float operations and rapid high-rate discharge bursts. Its rugged internal lead straps and low-resistance plate grouping promote immediate current transfer, maintaining stable voltage output even under cold ambient conditions. Housed in a resilient, impact-resistant ABS container weighing a lightweight 0.72kg, this battery is built to withstand mechanical stress while fitting tightly into standardized compact enclosures.
| Параметр | Технические характеристики |
|---|---|
| Марка и модель | Sinergy SIN6-4.5 (SIN6-45) |
| Номинальное напряжение | 6V (3 Cells @ 2.0V nominal) |
| Номинальная ёмкость (по 20-часовому стандарту) | 4.5 Ah |
| Химический состав аккумулятора | Valve Regulated Lead-Acid (VRLA / AGM) |
| Тип терминала | Faston Tab F1 (0.187 inch / 4.75 mm) |
| Размеры (Д × Ш × В) | 70 mm x 47 mm x 99 mm (Total Height: 105 mm) |
| Product Weight | 0.72 kg (1.59 lbs) |
| Материал корпуса | Ul94-HB High-Impact ABS Plastic |
| Internal Resistance | Approx. 19 mOhm (Fully Charged at 25°C) |
| Float Charging Voltage | 6.75V to 6.90V at 25°C (77°F) |
| Cyclic Charging Voltage | 7.20V to 7.50V at 25°C (77°F) |
| Maximum Charging Current | 1.35 A |
Due to its 6V 4.5Ah form factor and F1 Faston terminal structure, the Sinergy SIN6-4.5 is strictly not intended for standard 12V automotive starting, lighting, and ignition (SLI) systems or micro-hybrid automotive start-stop engines. Standard passenger cars require heavy-duty 12V multi-cell batteries boasting hundreds of Cold Cranking Amps (CCA). Installing a small 6V battery in place of a 12V starter battery will lead to immediate electrical malfunction, severe under-voltage faults, and charging system damage.
Instead, this battery excels in targeted low-voltage vehicle and auxiliary environments. It serves as an OEM-grade replacement power unit for 6V children ride-on toy vehicles, vintage classic motorbikes requiring 6-volt auxiliary systems, light motorized scooters, paddock equipment, portable emergency equipment, uninterruptible power supply (UPS) backups, automated gate motors, medical devices, and security alarm panels. When wired in series configurations (such as two identical units paired for 12V), it can support specialized low-draw powersports telemetry, telemetry trackers, and onboard auxiliary instruments.
Safe installation begins with verifying correct terminal polarity. The Sinergy SIN6-4.5 features standard F1 blade terminals, color-coded with red polarity markings for positive (+) and black markings for negative (-). Always inspect connector push-on terminals for corrosion, oxidation, or loose crimps before mating. Ensure female F1 connectors slide firmly and squarely onto the battery tabs to prevent high-resistance contact points that generate localized heat.
Because this unit employs sealed VRLA recombinant technology, it requires zero water replenishment throughout its operating life. Never attempt to pry open the top sealing vents. For maximum operational life, utilize a dedicated smart multistage charger configured for 6V AGM batteries. Avoid deep discharges beneath 5.25V total cut-off threshold (1.75V per cell), as repeated deep depletion causes severe plate sulfation. If stored seasonally, maintain the battery in a cool, dry room at approximately 20°C to 25°C and provide a top-up refresh charge every 3 to 6 months to prevent capacity loss.
No. A single Sinergy SIN6-4.5 delivers 6V nominal potential, which is insufficient for standard 12V vehicle electrical architectures. Connecting a single 6V battery to a 12V car electrical system will cause vehicle electronics to fail. However, two identical SIN6-4.5 units can be wired in series (positive to negative) to supply 12V for low-draw auxiliary devices.
Lead-acid electrochemistry yields approximately 2.0V to 2.1V nominal per individual cell. A 6-volt battery is constructed from 3 series-connected internal cells (3 x 2.0V = 6V). This differs from a standard 12V automotive battery, which contains 6 internal cells.
The battery is equipped with standard Faston F1 terminals measuring 4.75mm (0.187 inches) in width. These quick-disconnect tabs accept standard push-on female spade connectors commonly found in backup alarms, toys, and emergency lighting systems.
Yes. The Sinergy SIN6-4.5 uses non-spillable VRLA AGM technology where the electrolyte is completely suspended within micro-fiber glass mats. The battery can be safely installed and operated in upright or lateral (side) orientations without risk of acid leakage.
For standby or float applications (such as alarm systems and UPS units), float charge between 6.75V and 6.90V at 25°C. For regular cyclic use (such as electric ride-on toys), charge between 7.20V and 7.50V with an initial current not exceeding 1.35 Amps.
| Вес | 6967131678 кг |
|---|---|
| Габариты | 7 × 4.7 × 9.9 см |
Подтвержденные технические характеристики, информация о совместимости автомобилей и ответы на вопросы по техническому обслуживанию.
No. The Sinergy SIN6-4.5 is a low-capacity VRLA (Valve Regulated Lead-Acid) auxiliary battery engineered for standby power and low-drain cyclic applications, not automotive SLI (Starting, Lighting, Ignition) duties. Vehicles with modern Start-Stop systems demand high-rate automotive AGM or EFB starter batteries capable of delivering hundreds of Cold Cranking Amps (CCA) and enduring severe micro-cycling. Using this compact 4.5Ah unit for vehicle starting will result in immediate voltage collapse and internal plate damage.
This VRLA battery must be charged using an intelligent, voltage-regulated multi-stage smart charger. For cycle service, apply a charging voltage of 2.40Vu20132.50V per cell (14.4Vu201315.0V for 12V rating, 7.2Vu20137.5V for 6V nominal) with maximum charging current limited to 0.25C (approx. 1.1A). For standby/float applications, maintain 2.25Vu20132.30V per cell (13.5Vu201313.8V for 12V, 6.75Vu20136.90V for 6V) at 25u00b0C. Never connect unregulated automotive high-current boost chargers, as excessive current causes electrolyte dry-out and thermal runaway.
Under standard float/standby conditions at an optimal ambient temperature of 20u00b0C to 25u00b0C, the Sinergy SIN6-4.5 has a design service life of 3 to 5 years (or approximately 250 to 300 cycles at 100% Depth of Discharge). Most commercial distributions supply a standard 12-month manufacturer limited warranty covering manufacturing defects. Operating the battery continuously above 30u00b0C or leaving it in a discharged state will significantly accelerate grid corrosion and shorten actual operating life.
Because this is an auxiliary standby VRLA battery, it does not carry an automotive Cold Cranking Amps (CCA) rating. In sub-zero temperatures (down to -15u00b0C or lower), internal chemical resistance rises sharply, reducing usable capacity by 30% to 40% and limiting instantaneous current output. To preserve performance in winter conditions, keep the battery maintained at 100% state of charge to prevent the electrolyte from freezing, as a discharged lead-acid battery freezes at temperatures just below 0u00b0C.
Yes, it is 100% maintenance-free with sealed valve-regulated construction and internal gas recombination, eliminating the need to check or add distilled water. It can be installed in upright or sideways orientations, but never completely inverted. The terminals (typically Faston tabs) are polarity-marked with red for positive (+) and black for negative (-); cross-polarity installation will cause electrical shorting, arc flash, or equipment damage. Always use insulated hand tools and install in a clean, ventilated compartment away from ignition sources.

UPS & Alarm Backup Batteries

UPS & Alarm Backup Batteries

UPS & Alarm Backup Batteries

UPS & Alarm Backup Batteries


Made with ♥ by eMarketing Cyprus